Sanuvox R1700GX Bedienungsanleitung Seite 2

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 2
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 1
Step-By-Step Instruction Guide
Follow separate Foam Gasket Instructions
to install the 4 four foam strips on the Backplate.
Carefully break Security Seal located on the
underside of the Lamp cardboard sleeve.
Carefully slide Lamp out from protective sleeve. Be
sure to use cotton gloves (included) guaranteeing a
clean Lamp free from fingerprints.
Slide the Lamp’s porcelain end-cap (with the 4 pins)
through clamp bracket. Be sure to notice the
Tension Lever is down.
Tension Lever
is DOWN
Once the Lamp’s end-cap is in place, pull the
Tension Lever UP to lock the Lamp in place. If the
Lever is loose, just turn Lever clockwise a turn or so.
Tension Lever
is UP locking
Lamp in place
While holding the SAME side of the Lamp attached
to the clamp, carefully push on the white plug.
NOTE: Although the Lamp is fairly strong, too much tension from
the opposing side may break the Lamp.
Once Lamp is installed, place and screw Turbulator to
the top of the Reflecting Tube. The air must pass
through this Turbulator as it enter the Reflecting Tube.
Cut-out the ‘Smart Template’ from the side of the
Purifier’s outer carton.
Did you throw
out the box?
Don’t worry!
Just cut a 8” x
6.25” opening
into the duct!
Draw around the ‘Smart Template’ outlining where
the Purifier will be installed
Return or Supply
Installation?
We suggest
Return, but
can be easily
installed on the
Supply.
Cut around outline.
Angle the purifier so it easily fits into the duct
opening.
Use the self-taping screws (included) to mount
the purifier to the duct .Hard-wire the purifier to
the Electronic Air Cleaner Terminal or Fan Relay.
Only break the
security seal
AFTER you
visually inspect
the Lamp.
1
3
4
5
6
7
8
10
11
12
2
9
If the White Plug
does not push
on easily, just
rotate the plug
180º
Up-flow System?
Horizontal duct?
Not a problem. The
Reflecting Tube &
Lamp are easily
rotatable 180°.
Just visit back
page for
instructions.
R1700
INSTALLATION
MANUAL
BALLAST ON = GREEN
LAMP ON = BLUE
When the HVAC fan is on, both LED
lights should be on.
If the Ballast (Green) LED is on and
the Lamp (Blue) LED is off, the UV
Lamp is not functioning.
If both the Ballast (Green) LED is off
and the Lamp (Blue) LED is off, the
ballast is not functioning.
Visit the back page for
wiring instructions and the Trouble
Shooting.
Understanding The ‘Smart System’ LED Status Display
Congratulations on the purchase & installation of your new Sanuvox Ultraviolet Air Purifier. Sanuvox UV Air Purifiers are the
most advanced Air Purification System available having been proven to destroy up to 99.999% of Biological & chemical
contaminants that circulate throughout your home or facility. Sanuvox Systems have been tested by The EPA (Environmental
Protection Agency), The National Homeland Security Research Center, Medical Universities and Independent 3rd Party
Laboratories.
(1) x R1700
(1) x Pair of Gloves
(1) x UV ‘J’ Lamp
(1) x Turbulator
(6) x Screws 3/8
(2) x Screws
(1) x Lamp Date Decal
(1) x Warranty Card
(1) x Product Brochure
(1) x Foam Gasket Directions
(1) x Commercial Q & A
Literature Package
TOOLS REQUIRED
(1) x Foam Gasket
Phillips Head
Screwdriver
Pair of Snips or saw
THIS BOX CONTAINS
Seitenansicht 1
1 2

Kommentare zu diesen Handbüchern

Keine Kommentare